Muskingum Flood Routing
Route the inflow hydrograph through a river reach having time constant k= 12 hour and weighing factor x = 0.2
C_o=\frac{0 .5\mathit{\Delta}-kx}{k-kx+0 .5\mathit{\Delta}}
C_1=\frac{0 .5\mathit{\Delta}+kx}{k-kx+0 .5\mathit{\Delta}}
C_2=\frac{k-kx-0 .5\mathit{\Delta}}{k-kx+0 .5\mathit{\Delta}}